Talking about low-voltage power distribution cabinets, one of the types of power supply cabinets

Low-voltage distribution boxes are generally divided into strong current column head cabinets and weak current column head cabinets. The high-current row cabinet is a device used to manage and distribute mains power or UPS power, ( PLC control cabinet ) is often located at the end of a row of cabinets. For computer rooms with fault- tolerant requirements , high- current column head cabinets are usually located at both ends of a row of cabinets to achieve fault tolerance (n + n). Weak current column cabinets are mainly used for cable distribution in network wiring. There are too many weak cables in the computer room. A small computer room can manage all network cables through one or two main distribution frames. In large and medium-sized computer rooms, it is unimaginable to concentrate on the main distribution frame, so it is necessary to add 1 to 2 level column head cabinets to distribute cables. In a general computer room, the high current column head cabinet is located at one end of the cabinet ( inverter control cabinet), and the weak current column head cabinet is located at the other end; for the computer room with fault tolerance requirements , the general practice is that both ends are high current column head cabinets, and the weak current column head cabinet is located at the column head in the middle of the cabinet. The management function of the strong flow column head cabinet is very strong. A precision column head cabinet is now added to strengthen the management function of the high current column head cabinet. It can not only monitor conventional electrical parameters and switch status, but also detect neutral line current and dynamically adjust three-phase unbalance and other problems. The weak current column head cabinet is more inclined to power distribution, but after the electronic wiring system is added, the management function of the weak current column head cabinet is also greatly enhanced.

complete set of low-voltage distribution box manufacturers , will tell you:

1: Column head cabinets are generally divided into strong current column head cabinets and weak current column head cabinets. The high-current head cabinet is a device that manages and distributes mains power or UPS power, and is usually located at the end of the head cabinet. For computer rooms with fault- tolerant requirements , high- current column head cabinets are usually located at both ends of a row of cabinets to achieve fault-tolerant purposes (n, n). Weak current column cabinets are mainly used for cable distribution in network wiring. There are too many weak cables in the computer room. A small computer room can manage all network cables through one or two main distribution frames. In large and medium-sized computer rooms, it is unimaginable to concentrate on the main distribution frame, so it is necessary to add 1-2 stigma cabinets to distribute cables.

2: Generally, the strong current column head cabinet is located at one end of the cabinet in the computer room, and the weak current column head cabinet is located at the other end . The management function of the strong flow column head cabinet is very strong. A precision column head cabinet is now added to strengthen the management function of the high current column head cabinet. It can not only monitor conventional electrical parameters and switch status, but also detect neutral line current and dynamically adjust three-phase unbalance and other issues. The weak current column head cabinet is more inclined to power distribution, but after the electronic wiring system is added, the management function of the weak current column head cabinet is also greatly enhanced.