Many people don’t understand the management method of MPO optical fiber jumper dedicated to the data center. We must learn how to manage MTP/MPO and other related products correctly, which will bring a lot of benefits to our work.

Shengwei manufacturer tells you the management method of MPO optical fiber jumper dedicated to the data room

In the process of network reconfiguration, accessibility plays a crucial role, directly affecting the reliability of the network and the cost of network reconfiguration.

MPO fiber jumper management method

Based on the above factors affecting the performance and maintenance of fiber optic jumpers, we can deduce the following six methods to improve the flexibility and reliability of fiber jumper management:

  1. Pay attention to the bending radius of the fiber jumper.

Generally, fiber optic patch cords with a diameter of 1.6mm and 3.0mm can withstand a bending radius of not less than 3.5cm, while MPO fiber optic patch cords can withstand a bending radius of not less than 10 times its diameter.

  1. Do not pull or squeeze the fiber optic jumper.

When installing the special MPO fiber jumper for the data center, excessive force may cause pressure on the fiber jumper and connectors at both ends, affecting performance. It is worth noting that if you need to use a lot of force to pull the fiber optic jumper, there may be some problems in the middle.

Shengwei manufacturer tells you the management method of MPO optical fiber jumper dedicated to the data room

  1. Route the jumper according to the path of the fiber jumper.

If the existing patch cord length matches the current application, the patch cord can be reused, but it will still need to be removed from the fiber distribution frame and reinstalled according to the new path. Wire. In order to efficiently route patch cords, you should find a suitable path for the patch cords between two ports while avoiding patch cord weaving and crowding.

  1. Manage fiber patch cords in bundles or ribbons to keep the panel looking tidy.

Tightening or bundling fiber patch cables increases the risk of over-squeeze. To avoid this problem, you can properly “split” the fiber patch cord, allowing the fiber patch cord to move freely.

  1. Label.

Any administrative points of the network cabling infrastructure, including patch panels, must be properly marked so that network technicians can pinpoint where cables begin and end.

Shengwei manufacturer tells you the management method of MPO optical fiber jumper dedicated to the data room

  1. Check whether the fiber jumper is physically damaged.

This includes indentations and connector damage due to sudden bending of the boot.

The special MPO fiber jumper management method for the data center and the MPO bundled fiber jumper strengthen the management of the fiber jumper, which not only improves the reliability and flexibility of the fiber optic network system, but also reduces the operation and maintenance cost of the fiber optic network.