How to take over the modular cabinet in the equipment room

People in order to achieve the purpose of dust, usually put important equipment in a confined space, the problem is that the heat of these equipment is large, closed leading to the rapid rise of the internal temperature of the space, so the modular cabinet must be installed air conditioner heat dissipation.

 

 

 

People in order to achieve the purpose of dust, usually put important equipment in a confined space, the problem is that the heat of these equipment is large, closed leading to the rapid rise of the internal temperature of the space, so the modular cabinet must be installed air conditioner heat dissipation.

 

 

 

Electronic device faults are mostly caused by dust in the air. Dust may damage the hard disk, block the laser head, cover the heating element, short circuit, and fan shutdown caused by dust in the outdoor carbon equipment room.

 

 

 

Hazards of overtemperature in the equipment room

 

 

 

At the base temperature, for every 10 degrees of temperature rise, the reliability of the computer decreases by 25%. Disks and tapes can record errors due to thermal expansion. The master frequency of the computer’s clock will decrease because of the high temperature

 

 

 

UPS battery life is shortened at high temperature. Failure to handle these problems in a timely manner may cause machine damage, data loss, power short circuit, and fire accidents.

 

 

 

Usually we don’t pay much attention to power, except when it goes out. In fact: as a public power grid, the mains system is connected with thousands of various outdoor room loads, some of which are larger perceptual, capacitive, switching power supply and other loads, not only to obtain power from the grid, but also will in turn affect the quality of the grid deterioration. In addition, accidents of nature and people, such as earthquake, fire, lightning, power transmission and transformation system short circuit, will endanger the normal supply of power, thus affecting the normal work of the load.

 

 

 

Equipment room environment and equipment

 

 

 

  1. There should be good ventilation equipment in the machine room to ensure that the highest indoor temperature does not exceed 40℃. If the ventilation equipment cannot meet the requirements of the ambient temperature, air conditioning should be installed for cooling. When exhaust fans are used for ventilation, rain proof facilities should be installed outside the air outlet. For example, protective nets should be installed in outdoor equipment rooms at low installation heights.

 

 

 

  1. The normal lighting in the machine room is good, and there is an emergency lighting device. The equipment room must be equipped with fire extinguishing equipment.

 

 

 

The distribution box, cabinet and bridge should be well grounded and comply with the specifications. High and low voltage distribution cabinet, transformer formal power supply, meet the design function, according to the relevant national and regional regulations construction, no accident and safety risks (such as cable trench cover; There is a hanging safety sign; Safe and effective distance qualified; Isolation facilities on the high pressure side); Grounding network reliable grounding; “Three prevention” measures should be taken in the equipment room (such as rat proof plate, cable trench, door, window, wall hole with net sealing, wire trough into the equipment room through the wall section should be sealed with fire mud).

 

Shanghai Hujue Network Communication Equipment Co., LTD., through the integration of product innovation and two-way management mode, has achieved great performance in product intelligent service and service information value-added, focusing on outdoor rainproof, outdoor air conditioning, outdoor beautification, outdoor base station and other cabinets.